Description
LM32686 – Leeson 40 HP General Purpose Motor, 3 phase, 1800 RPM, 230/460 V, 324TS Frame, TEFC – LM32686
LM32686 Leeson Three Phase TEFC Motors
Please advise CFM, static pressure, voltage, phase, and/or horsepower on specifications, drawings, or existing equipment for an accurate quote.
General Specifications
UPC: | 691720021163 | Weight: | 504 LB |
Packaged Length: | 32 IN | Packaged Width: | 26.25 IN |
Packaged Height: | 21.95 IN |
Nameplate Specifications
Output HP: | 40 Hp | Output KW: | 30.0 kW |
Frequency: | 60/50 Hz | Voltage: | 230/460 V |
Current: | 101.0/50.5 A | Speed: | 1780 rpm |
Service Factor: | 1.25 | Phase: | 3 |
Efficiency: | 94.1 % | Power Factor: | 79.5 |
Duty: | Continuous | Insulation Class: | F |
Design Code: | B | KVA Code: | F |
Frame: | 324TS | Enclosure: | Totally Enclosed Fan Cooled |
Thermal Protection: | No | Ambient Temperature: | 40 °C |
Drive End Bearing Size: | 6311 | Opp Drive End Bearing Size: | 6309 |
UL: | Recognized | CSA: | Y |
CE: | Y | IP Code: | 43 |
Technical Specifications
Electrical Type: | Squirrel Cage Induction Run | Starting Method: | Wye Start Delta Run |
Poles: | 4 | Rotation: | Reversible |
Resistance Main: | .118 Ohms | Mounting: | Rigid base |
Motor Orientation: | Horizontal | Drive End Bearing: | Ball |
Opp Drive End Bearing: | Ball | Frame Material: | Rolled Steel |
Shaft Type: | TS | Overall Length: | 27.00 in |
Frame Length: | 15.50 in | Shaft Diameter: | 1.875 in |
Shaft Extension: | 3.75 in | Assembly/Box Mounting: | F1/F2 CAPABLE |
Speed Characteristics
Curvepoint | Current (Amps) | Current (%) | Torque (ft-lbs) | (%) | Speed (RPM) | Rated Output (KW) | Power Factor (%) | Rated Output (Hp) |
No Load | 20.00 | 39.5 | 0.00 | 0.0 | 1,800 | 3.5 | 40.00 | |
Locked-Rotor | 270.00 | 535.0 | 215.00 | 183.0 | 0 | 32.0 | 40.00 | |
Pull-Up | 243.00 | 481.0 | 183.00 | 155.0 | 900 | 40.00 | ||
1/3 | 255.00 | 505.0 | 183.00 | 155.0 | 600 | 40.00 | ||
Full Load | 50.50 | 100.0 | 118.00 | 100.0 | 1,780 | 79.5 | 40.00 | |
2/3 | 230.00 | 455.0 | 194.00 | 164.0 | 1,200 | 40.00 | ||
Break-Down | 148.00 | 293.0 | 250.00 | 212.0 | 1,735 | 63.5 | 40.00 |
Load Characteristics
% of Rated Load | 0 % | 25 % | 50 % | 75 % | 100 % | 115 % | 125 % |
Current (Amps) | 20.00 | 24.00 | 31.00 | 40.00 | 50.50 | 57.00 | 62.00 |
Rated Output (KW) | 1.20 | 8.40 | 16.10 | 24.00 | 32.00 | 37.00 | 40.00 |
Efficiency (%) | 0.0 | 89.5 | 93.0 | 94.1 | 94.1 | 93.6 | 93.6 |
Power Factor (%) | 3.5 | 43.5 | 65.0 | 75.0 | 79.5 | 80.5 | 81.0 |
Speed (RPM) | 1,800 | 1,795 | 1,790 | 1,785 | 1,780 | 1,778 | 1,775 |
Temp. Rise @ FL | 0.0 | 0.0 | 0.0 | 0.0 | 45.0 | 65.0 | 80.0 |
Torque (ft-lbs) | 0.00 | 29.50 | 58.50 | 88.00 | 118.00 | 136.00 | 148.00 |