Description
145TBWD5335 – Marathon 2 HP Washdown Motor, 1 phase, 1800 RPM, 115/230 V, 145TC Frame, TEFC – N349
145TBWD5335 Marathon Paint Free NEMA Washdown Motors
Please advise CFM, static pressure, voltage, phase, and/or horsepower on specifications, drawings, or existing equipment for an accurate quote.
General Specifications
UPC: | 722856131645 | Weight: | 53 LB |
Packaged Length: | 17 IN | Packaged Width: | 11.57 IN |
Packaged Height: | 11.66 IN |
Nameplate Specifications
Output HP: | 2 Hp | Output KW: | 1.5 kW |
Frequency: | 60 Hz | Voltage: | 115/230 V |
Current: | 16.4/8.2 A | Speed: | 1725 rpm |
Service Factor: | 1.15 | Phase: | 1 |
Efficiency: | 74 % | Power Factor: | 98 |
Duty: | Continuous | Insulation Class: | F |
Design Code: | N | KVA Code: | J |
Frame: | 145TC | Enclosure: | Totally Enclosed Fan Cooled |
Thermal Protection: | No | Ambient Temperature: | 40 °C |
Drive End Bearing Size: | 6205 | Opp Drive End Bearing Size: | 6203 |
UL: | Recognized | CSA: | Y |
CE: | Y | IP Code: | 55 |
Technical Specifications
Electrical Type: | Capacitor Start Capacitor Run | Starting Method: | Across The Line |
Poles: | 4 | Rotation: | Selective Counterclockwise |
Resistance Main: | .87 Ohms | Mounting: | Rigid base |
Motor Orientation: | HORIZONTAL | Drive End Bearing: | BALL |
Opp Drive End Bearing: | BALL | Frame Material: | Stainless Steel |
Shaft Type: | T | Overall Length: | 14.00 in |
Frame Length: | 9.00 in | Shaft Diameter: | 0.875 in |
Shaft Extension: | 2.24 in | Assembly/Box Mounting: | F1 ONLY |
Speed Characteristics
Curvepoint | Current (Amps) | Current (%) | Torque (ft-lbs) | (%) | Speed (RPM) | Rated Output (KW) | Power Factor (%) | Rated Output (Hp) |
Break-Down | 30.10 | 353.0 | 14.10 | 235.0 | 1,500 | 7.41 | 0.0 | 2.00 |
Full Load | 8.53 | 100.0 | 6.00 | 100.0 | 1,741 | 1.81 | 0.0 | 2.00 |
Locked-Rotor | 57.50 | 674.0 | 14.00 | 233.0 | 0 | 10.19 | 0.0 | 2.00 |
No Load | 4.32 | 51.0 | 0.00 | 0.0 | 1,797 | 0.19 | 0.0 | 2.00 |
Pull-Up | 0.00 | 0.0 | 13.00 | 217.0 | 156 | 0.00 | 0.0 | 2.00 |
Load Characteristics
% of Rated Load | 0 % | 25 % | 50 % | 75 % | 100 % | 125 % | 150 % |
Current (Amps) | 4.32 | 4.72 | 5.91 | 7.42 | 8.53 | 11.27 | 13.58 |
Rated Output (KW) | 0.19 | 0.55 | 0.95 | 1.36 | 1.81 | 2.28 | 2.78 |
Efficiency (%) | 0.0 | 69.7 | 79.3 | 82.6 | 82.2 | 81.1 | 78.8 |
Power Factor (%) | 19.0 | 50.3 | 70.2 | 79.9 | 92.0 | 87.8 | 88.9 |
Speed (RPM) | 1,797 | 1,787 | 1,775 | 1,763 | 1,741 | 1,732 | 1,713 |
Temp. Rise @ FL | 0.0 | 0.0 | 0.0 | 0.0 | 94.0 | 0.0 | 0.0 |
Torque (ft-lbs) | 0.00 | 1.50 | 3.00 | 4.50 | 6.00 | 7.50 | 9.00 |