Description
117273.00 – Leeson 1 HP Washdown Motor, 3 phase, 3600 RPM, 230/460 V, 56HC Frame, TENV – 117273.00
117273.00 Leeson 3 Phase Motors
Please advise CFM, static pressure, voltage, phase, and/or horsepower on specifications, drawings, or existing equipment for an accurate quote.
General Specifications
UPC: | 691720021293 | Weight: | 48 LB |
Packaged Length: | 19.5 IN | Packaged Width: | 10.44 IN |
Packaged Height: | 10.88 IN |
Nameplate Specifications
Output HP: | 1 Hp | Output KW: | 0.75 kW |
Frequency: | 60/50 Hz | Voltage: | 230/460 V |
Current: | 2.6/1.3 A | Speed: | 3450 rpm |
Service Factor: | 1.15 | Phase: | 3 |
Efficiency: | 85.5 % | Power Factor: | 85 |
Duty: | Continuous | Insulation Class: | F |
Design Code: | B | KVA Code: | L |
Frame: | 56HC | Enclosure: | Totally Enclosed Non Ventilated |
Thermal Protection: | No | Ambient Temperature: | 40 °C |
Drive End Bearing Size: | 6205 | Opp Drive End Bearing Size: | 6205 |
UL: | Recognized | CSA: | Y |
CE: | Y | IP Code: | 56 |
Technical Specifications
Electrical Type: | Squirrel Cage Inverter Rated | Starting Method: | Line Or Inverter |
Poles: | 2 | Rotation: | Reversible |
Resistance Main: | 13.15 Ohms | Mounting: | Rigid Base |
Motor Orientation: | Horizontal | Drive End Bearing: | Ball |
Opp Drive End Bearing: | Ball | Frame Material: | Stainless Steel |
Shaft Type: | NEMA 56 | Overall Length: | 13.22 in |
Frame Length: | 7.00 in | Shaft Diameter: | 0.625 in |
Shaft Extension: | 1.88 in | Assembly/Box Mounting: | F1 ONLY |
Speed Characteristics
Curvepoint | Current (Amps) | Current (%) | Torque (ft-lbs) | (%) | Speed (RPM) | Rated Output (KW) | Power Factor (%) | Rated Output (Hp) |
No Load | 0.54 | 42.0 | 0.00 | 0.0 | 3,589 | 0.13 | 30.4 | 1.00 |
Locked-Rotor | 12.20 | 953.0 | 78.30 | 326.0 | 0 | 6.02 | 0.0 | 1.00 |
Full Load | 1.28 | 100.0 | 24.00 | 100.0 | 3,503 | 0.88 | 86.5 | 1.00 |
Break-Down | 7.46 | 583.0 | 111.40 | 464.0 | 2,557 | 4.86 | 0.0 | 1.00 |
Pull-Up | 11.30 | 883.0 | 78.20 | 326.0 | 528 | 5.99 | 0.0 | 1.00 |
Load Characteristics
% of Rated Load | 0 % | 25 % | 50 % | 75 % | 100 % | 115 % | 125 % | 150 % |
Current (Amps) | 0.54 | 0.63 | 0.81 | 1.04 | 1.28 | 1.43 | 1.56 | 1.84 |
Rated Output (KW) | 0.13 | 0.28 | 0.48 | 0.68 | 0.88 | 1.01 | 1.10 | 1.33 |
Efficiency (%) | 0.0 | 68.4 | 79.5 | 83.0 | 84.5 | 84.8 | 83.9 | 83.2 |
Power Factor (%) | 30.4 | 55.4 | 73.8 | 81.9 | 86.6 | 88.4 | 88.8 | 90.4 |
Speed (RPM) | 3,589 | 3,571 | 3,550 | 3,528 | 3,503 | 3,486 | 3,478 | 3,450 |
Temp. Rise @ FL | 0.0 | 0.0 | 0.0 | 0.0 | 98.0 | 114.0 | 0.0 | 0.0 |
Torque (ft-lbs) | 0.00 | 6.00 | 12.00 | 18.00 | 24.00 | 27.60 | 30.00 | 36.00 |