Description
113914.00 – Leeson 1 HP Special Voltage Motor, 1 phase, 3000 RPM, 110/220 V, 56C Frame, TEFC – 113914.00
113914.00 Leeson 50 Hz Motors
Please advise CFM, static pressure, voltage, phase, and/or horsepower on specifications, drawings, or existing equipment for an accurate quote.
General Specifications
UPC: | 691720012765 | Weight: | 35 LB |
Packaged Length: | 14.44 IN | Packaged Width: | 10.44 IN |
Packaged Height: | 10.88 IN |
Nameplate Specifications
Output HP: | 1 Hp | Output KW: | 0.75 kW |
Frequency: | 50 Hz | Voltage: | 110/220 V |
Current: | 13.2/6.6 A | Speed: | 2850 rpm |
Service Factor: | 1 | Phase: | 1 |
Efficiency: | 66 % | Power Factor: | 78 |
Duty: | Continuous | Insulation Class: | B |
Design Code: | No Design Code | KVA Code: | J |
Frame: | 56C | Enclosure: | Totally Enclosed Fan Cooled |
Thermal Protection: | No | Ambient Temperature: | 40 °C |
Drive End Bearing Size: | 6203 | Opp Drive End Bearing Size: | 6203 |
UL: | Recognized | CSA: | Y |
CE: | Y | IP Code: | 54 |
Technical Specifications
Electrical Type: | Capacitor Start Induction Run | Starting Method: | Across The Line |
Poles: | 2 | Rotation: | Selective Counterclockwise |
Resistance Main: | 0 Ohms | Mounting: | Round |
Motor Orientation: | Horizontal | Drive End Bearing: | Ball |
Opp Drive End Bearing: | Ball | Frame Material: | Rolled Steel |
Shaft Type: | NEMA 56 | Overall Length: | 11.98 in |
Frame Length: | 6.50 in | Shaft Diameter: | 0.625 in |
Shaft Extension: | 1.88 in | Assembly/Box Mounting: | F1 Only |
Speed Characteristics
Curvepoint | Current (Amps) | Current (%) | Torque (ft-lbs) | (%) | Speed (RPM) | Rated Output (KW) | Power Factor (%) | Rated Output (Hp) |
Full Load | 6.60 | 100.0 | 28.80 | 100.0 | 2,850 | 0.00 | 0.0 | 1.00 |
Break-Down | 0.00 | 0.0 | 80.00 | 278.0 | 2,500 | 0.00 | 0.0 | 1.00 |
Pull-Up | 0.00 | 0.0 | 72.00 | 250.0 | 2,300 | 0.00 | 0.0 | 1.00 |
Locked-Rotor | 33.00 | 500.0 | 80.00 | 278.0 | 0 | 0.00 | 0.0 | 1.00 |
Load Characteristics
% of Rated Load | 0 % | 25 % | 50 % | 75 % | 100 % | 115 % | 125 % |
Current (Amps) | 4.40 | 4.50 | 4.85 | 5.55 | 6.60 | 7.20 | 7.45 |
Rated Output (KW) | 0.22 | 0.40 | 0.60 | 0.82 | 1.06 | 1.22 | 1.32 |
Efficiency (%) | 0.0 | 46.7 | 62.5 | 68.1 | 70.3 | 70.5 | 71.0 |
Power Factor (%) | 2.7 | 40.6 | 56.0 | 67.5 | 73.3 | 76.8 | 80.2 |
Speed (RPM) | 3,000 | 2,975 | 2,960 | 2,940 | 2,915 | 2,905 | 2,895 |
Temp. Rise @ FL | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 83.0 | 0.0 |
Torque (ft-lbs) | 0.00 | 7.10 | 14.22 | 21.50 | 28.90 | 33.30 | 36.30 |