Description
113300.00 – Leeson 1.50 HP Washdown Motor, 1 phase, 1800 RPM, 115/208-230 V, 56HC Frame, TEFC – 113300.00
113300.00 Leeson White Epoxy General Purpose Motors
Please advise CFM, static pressure, voltage, phase, and/or horsepower on specifications, drawings, or existing equipment for an accurate quote.
General Specifications
UPC: | 691720011850 | Weight: | 45 LB |
Packaged Length: | 14.44 IN | Packaged Width: | 10.44 IN |
Packaged Height: | 10.88 IN |
Nameplate Specifications
Output HP: | 1.50 Hp | Output KW: | 1.1 kW |
Frequency: | 60 Hz | Voltage: | 115/208-230 V |
Current: | 19.0/9.5 A | Speed: | 1725 rpm |
Service Factor: | 1.15 | Phase: | 1 |
Efficiency: | 71 % | Power Factor: | 72 |
Duty: | Continuous | Insulation Class: | F |
Design Code: | No Design Code | KVA Code: | J |
Frame: | 56HC | Enclosure: | Totally Enclosed Fan Cooled |
Thermal Protection: | No | Ambient Temperature: | 40 °C |
Drive End Bearing Size: | 6205 | Opp Drive End Bearing Size: | 6203 |
UL: | Recognized | CSA: | Y |
CE: | N | IP Code: | 55 |
Technical Specifications
Electrical Type: | Capacitor Start Induction Run | Starting Method: | Across The Line |
Poles: | 4 | Rotation: | Selective Counterclockwise |
Resistance Main: | 0 Ohms | Mounting: | Rigid Base |
Motor Orientation: | Horizontal | Drive End Bearing: | Ball |
Opp Drive End Bearing: | Ball | Frame Material: | Rolled Steel |
Shaft Type: | NEMA 56 | Overall Length: | 13.37 in |
Frame Length: | 7.50 in | Shaft Diameter: | 0.625 in |
Shaft Extension: | 1.88 in | Assembly/Box Mounting: | F1 Only |
Speed Characteristics
Curvepoint | Current (Amps) | Current (%) | Torque (ft-lbs) | (%) | Speed (RPM) | Rated Output (KW) | Power Factor (%) | Rated Output (Hp) |
Pull-Up | 42.05 | 422.0 | 81.00 | 150.0 | 1,175 | 7.01 | 0.0 | 1.50 |
Break-Down | 31.72 | 318.0 | 150.00 | 278.0 | 1,500 | 6.32 | 0.0 | 1.50 |
Locked-Rotor | 50.95 | 512.0 | 150.00 | 278.0 | 0 | 9.76 | 0.0 | 1.50 |
Full Load | 9.96 | 100.0 | 54.00 | 100.0 | 1,749 | 1.62 | 0.0 | 1.50 |
Load Characteristics
% of Rated Load | 0 % | 25 % | 50 % | 75 % | 100 % | 125 % | 150 % |
Current (Amps) | 6.29 | 6.55 | 7.35 | 8.40 | 9.72 | 11.35 | 13.34 |
Rated Output (KW) | 0.27 | 0.58 | 0.90 | 1.23 | 1.58 | 1.98 | 2.43 |
Efficiency (%) | 0.0 | 48.9 | 62.7 | 68.5 | 70.4 | 69.9 | 67.3 |
Power Factor (%) | 18.9 | 38.7 | 53.4 | 63.7 | 70.8 | 75.6 | 79.0 |
Speed (RPM) | 1,795 | 1,783 | 1,771 | 1,759 | 1,743 | 1,726 | 1,704 |
Temp. Rise @ FL | 0.0 | 0.0 | 0.0 | 0.0 | 105.0 | 0.0 | 0.0 |
Torque (ft-lbs) | 0.00 | 18.00 | 36.00 | 54.00 | 72.00 | 90.00 | 108.00 |